English 中文
HOT PRODUCTS
Crimp Headspace Vial1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8
1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8
Details Products name 1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8 Dimension 8mm Cap Color White and Black Septa details White,Red,Blue,1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and c...
Crimp Headspace Vial1.5ml 9mm Short Thread Autosampler Vials ND9
1.5ml 9mm Short Thread Autosampler Vials ND9
Details Products name 1.5mL 9mm Short Thread Autosampler Vial ND9 Dimension 9mm Cap Color Blue, Black, Red, Yellow Septa details White,Red,Blue,1mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and ...
Crimp Headspace Vial1.5ml 10-425 Screw Autosampler Vials ND10
1.5ml 10-425 Screw Autosampler Vials ND10
Details Products name 1.5ml 10-425 Screw Autosampler Vials ND10 Dimension 10mm Cap Color Black Septa details White,Red,1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1.  1.5ml 10-425 Scre...
Crimp Headspace Vial1.5mL 11mm Crimp Ring Autosampler Vial ND11
1.5mL 11mm Crimp Ring Autosampler Vial ND11
Details Products name 1.5mL 11mm Crimp Ring Autosampler Vial ND11 Dimension 11mm Cap Color Silver Septa details White, Red,1mm thickness. Material Aluminum for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1. ...
Crimp Headspace Vial1.5mL 11mm Snap Ring Autosampler Vial ND11
1.5mL 11mm Snap Ring Autosampler Vial ND11
Details Products name 1.5mL 11mm Snap Ring Autosampler Vial ND11 Dimension 11mm Cap Color Natural, Blue, Red Septa details White, Red, Blue,1mm thickness. Material PE for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory...
Crimp Headspace Vial4mL 13-425 Screw Neck Autosampler Vial ND13
4mL 13-425 Screw Neck Autosampler Vial ND13
Details Products name 4mL 13-425 Screw Neck Autosampler Vial ND13 Dimension 13mm Cap Color Black Septa details White, Red, Nature 1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, open top Septa type Non-slit Description 4 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1...
Crimp Headspace Vial16mm Test Tubes for Water Analysis
16mm Test Tubes for Water Analysis
Details Products name 16mm Test Tubes for Water Analysis Dimension 16mm Cap Color White Material PC for Cap, PTFE/Silicone for Septa Package 100pcs/Pack or 25pcs/Pack Cap type Close top Septa type Non-slit Description COD vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, Headspace vials and COD vials at factory price. 1. PTFE Septa for 16mm test tube Closures, W...
Crimp Headspace Vial20-60mL 24-400 Screw Neck Storage Vial ND24
20-60mL 24-400 Screw Neck Storage Vial ND24
Details Products name 20-60mL 24-400 Screw Neck Storage Vial ND24 Dimension 24mm Cap Color Black, White Septa details Nature,3mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top, Close top Septa type Non-slit Description Sample Storage vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply Sample Storage vials, septa and caps at factory pr...
Our Company
Zhejiang Aijiren Technology Co., Ltd. is a global supplier of Headspace Vials in the field of analysis with high quality, excellent service and preferential prices. Aijiren's customers come from the pharmaceutical, life sciences, chemistry, technology, food processing and other industries. These industries all need Headspace GC Vial for testing. Others such as universities, research institutions, governments, environmental testing institutions, etc. also often buy GC Vial from Aijiren for Gas Chromatography.
20
+ years
Experience Accumulation
Technical Improvement
200/30
Embloyees and Senior Engineers
Best GC Vial Production Process
10000
Square Meters of Floor Space
Advanced Production Scale and Capacity
300+
Analytical Laboratories
Government Infrastructure Project Partner
Total Customers All Over the World
Headspace Vial on Sale
GC Vial Supplier
GC Vial Manufacturer
Aijiren Headspace Vial
The Australian Customer’s V947 Autosampler Vial Order is CompletedCrimp Top Headspace Vial
The Australian Customer’s V947 Autosampler Vial Order is Completed
View More
American Customer Ordered 100,000 Boxes of 9-425 2ml HPLC VialsCrimp Top Headspace Vial
American Customer Ordered 100,000 Boxes of 9-425 2ml HPLC Vials
View More
5000-boxes-of-blue-screw-cap-10-425-hplc-vial-sent-to-singaporeCrimp Top Headspace Vial
5000-boxes-of-blue-screw-cap-10-425-hplc-vial-sent-to-singapore
View More
Dividing the quoted price by 100 is not a cost per testnew gc vial
Dividing the quoted price by 100 is not a cost per test
A procurement manager sent me a spreadsheet last quarter showing two 9 mm screw-thread vials: one at $0.11 per unit and one at $0.19 per unit. She had already decided to switch to the cheaper one. Then I asked how many vials her lab consumed per 100 reported results, and she did not have that number. When we pulled the batch records, the answer was 118 for the cheap vial and 104 for the more expensive one, and the cheap vial carried a 6.2% reject rate on the autosampler. The gc vial cost pe...
Which GC vial changes force revalidation and which only need verificationnew gc vial
Which GC vial changes force revalidation and which only need verification
A 40-vial sequence on a split/splitless inlet came back with the internal standard area drifting 6.8% low across the run, and the check standard failed at injection 31. The column was three weeks old, the inlet liner had 180 injections on it, and the septa had been changed that morning. The actual cause was a supplier switch on the GC vial: the new lot had a 0.5 mm thinner crimp flange, and 14 of the 40 caps sat 0.2 mm low enough that the autosampler needle entered at a slight angle. Nothin...
Tray height is the first thing to measure, not the vialnew gc vial
Tray height is the first thing to measure, not the vial
Last March a customer sent back a tray of 120 vials from a lot that had run clean for three weeks. The autosampler had started throwing a pickup error at position 47, always the same position, never the same vial. We measured the tray: the rear-left corner sat 1.8 mm high against the front-right, well outside the ±0.5 mm the instrument expects. That is the kind of gc vial autosampler pickup error and misalignment that gets blamed on the vial and has nothing to do with it. The vials were fin...
Start with usable volume, not the nominal 2 mLnew gc vial
Start with usable volume, not the nominal 2 mL
A 2 mL vial filled to 1.8 mL leaves roughly 0.2 mL of headspace, and I have watched that exact fill volume turn a 150-injection sequence into a septa-failure study: the needle punched the same spot 150 times, the septum cored at injection 90, and the last 60 runs carried a silicone fragment peak at retention time 8.3 minutes. The chemist blamed the column. The problem was sizing: the vial was chosen for capacity, not for the injection count the method actually demanded. Getting gc vial capa...
Contact Emaii Whatsapp